AHUs are designed to save cost and energy
Published:  03 December, 2012
Flakt Woods, air handling unit, AHU

The eQ Prime range of air-handling units from Flakt Woods is designed to reduce capital costs and optimise energy savings. Available in eight sizes with airflows from 0.4 to 6 m3/s, these units are compact and fully controllable.

Energy-efficient permanent-magnet motors contribute to reducing specific fan power and, possibly, the overall size of the unit.

Another new component is the Semco energy-recovery wheel with high levels of moisture transfer and thermal efficiency to help reduce boiler and chiller loads.

Units also have Class F7 supply/extract features.

Other features include an energy-monitoring system, energy-saving night cooling mode, temperature regulation and cooling recovery. Other functions include constant air volume fan-flow control, filter monitoring and external fire alarm.

The handheld IP65 control panel is simple to use and has a magnetic backing so it can be attached to the casing of the air-handling unit.

Units are delivered in a single base frame that can be separated into three parts if necessary. The cased coils are under positive pressure to remove any condensation. Cased coils also reduce much of the installation work involved in supporting, connecting and insulating ductwork components.

Units can be delivered assembled or in a series of easily assembled blocks. Flakt Woods also takes care of commissioning and initial start-up procedure.

These AHUs can be monitored online using eQ Smart Web to check the health, readiness and performance of a unit on a daily basis.

Accessories include adjustable feet for the base frame, VAV pressure control and a time for extended or forced operation. Additional facade and room sensors for night cooling or heating are also available as is a CO2 sensor, PIR movement detector and zone control. A separate smoke detector and fire damper with accompanying control unit can be added.




Search

Welcome

Welcome to Modern Building Services Online, the web edition of Modern Building Services (MBS) journal and the UK's most popular Building Services engineering site. Modern Building Services covers the entire Building Services Engineering industry. This site contains archived content from the journal, plus web-specific content.

When you go to our digital edition, you can also access the archive of digital editions.
December 2018: DIGITAL EDITION

ARCHIVE OF DIGITAL EDITIONS

Modern Building services has a group
on Linkedin - join us!

Jobs

  • Senior Building Services Engineer

      Invitations are invited from experienced Building Services Engineers to assist in the development of a new division within an established professional practice. The projects will be predominantly with Defence-related and Government establishments but w......

  • Building Energy Management Systems (BEMS) Engineer

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

  • Engineering Technical Assistant

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

more jobs »

Poll

"Is the Building Services industry lagging behind in the implementation of BIM?"