Airedale overcomes space restrictions and noise issues for airport hotel

Published:  21 September, 2005

hotel
An Airedale air-cooled chiller system serving this new hotel at Stansted Airport overcomes severe space and noise restrictions.

To overcome space pressures and achieve low noise levels for air conditioning serving the Radisson SAS Hotel at Stansted Airport, Airedale has supplied two super-quiet Ultima remote air-cooled chillers.

They were specially designed to fit into a restricted space on the ground floor, which offered insufficient room for a chiller with air discharge from the top.

Since the hotel bedrooms are situated above the ground floor, where the cooling system is installed, and flights are restricted at night, it was crucial to design for low noise levels.

This £50 million world-class hotel has 500 bedrooms and 26 state-of-the-art meeting rooms.

A split air-cooled chiller system presented a viable solution and provides 1700 kW of cooling.

Vertical-coil condensers in a dedicated louvre enclosure were designed and made for this project by heat-exchanger manufacturer Guntner and make a significant contribution to meeting space and sound criteria. Variable fan-speed controllers are used inside the remote condenser panels, coupled with individual electronic fan-noise filters. — ensuring low fan speeds and low noise for night-time operation.

Paul Oliver, Airedale’s UK sales director, says, ‘The Radisson is a good example of manufacturers working with contractors to provide a solution. In partnership with Gunter and M&E design-and-build contractor Gratte Brothers, we made the cooling requirement work by reducing the footprint and designing a one-off split-chiller system for the client, with two chillers each providing 850 kW of cooling within restricted parameters. Quality was of the highest order, despite opening timescales presenting rigorous deadlines.’

File: loop (0b)


comments powered by Disqus

Search

Welcome

Welcome to Modern Building Services Online, the web edition of Modern Building Services (MBS) journal and the UK's most popular Building Services engineering site. Modern Building Services covers the entire Building Services Engineering industry. This site contains archived content from the journal, plus web-specific content.

When you go to our digital edition, you can also access the archive of digital editions.
December 2018: DIGITAL EDITION

ARCHIVE OF DIGITAL EDITIONS

Modern Building services has a group
on Linkedin - join us!

Jobs

  • Senior Building Services Engineer

      Invitations are invited from experienced Building Services Engineers to assist in the development of a new division within an established professional practice. The projects will be predominantly with Defence-related and Government establishments but w......

  • Building Energy Management Systems (BEMS) Engineer

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

  • Engineering Technical Assistant

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

more jobs »

Poll

"Is the Building Services industry lagging behind in the implementation of BIM?"