Studor confirms that air-admittance valves can be installed externally

Published:  03 May, 2017

air admittance valve, external, Studor, Wavin

Studor has responded to market confusion about air-admittance valves for drainage systems and whether they can be used externally positively. Technical director Steve White says, ‘Both our own Studor Maxi-Vent and the Wavin-branded Osmavent 110 can all be used externally. The latest BBA Agrément Certificates clearly state this and specifically refer to their external use.’

The BBA certificates verify that the AI-rated valves perform in extreme temperatures, from -20 to +60°C in accordance with EN12380. However, the independent testing carried out exceeded the requirements of the standard and proved that the valves operate in temperatures down to -40°C without the insulating cap. In addition, the ABS plastic of which the valves are made includes a UV stabiliser to protect against degradation effected from ultra-violet radiation.

The certificates note that these external AAVs should be installed with the aluminium cover and insulating cap which fits on top of the valve to protect the unit from birds, wildlife and accidental damage. The cover can be purchased separately and painted if there is a need to match a particular RAL colour.

Using an AAV externally allows a vent pipe to be terminated close to a window or other opening, so there is no need for additional pipework to locate it further away.

For more information on this story, click here: May 2017, 163

comments powered by Disqus

Search

Welcome

Welcome to Modern Building Services Online, the web edition of Modern Building Services (MBS) journal and the UK's most popular Building Services engineering site. Modern Building Services covers the entire Building Services Engineering industry. This site contains archived content from the journal, plus web-specific content.

When you go to our digital edition, you can also access the archive of digital editions.
December 2018: DIGITAL EDITION

ARCHIVE OF DIGITAL EDITIONS

Modern Building services has a group
on Linkedin - join us!

Jobs

  • Senior Building Services Engineer

      Invitations are invited from experienced Building Services Engineers to assist in the development of a new division within an established professional practice. The projects will be predominantly with Defence-related and Government establishments but w......

  • Building Energy Management Systems (BEMS) Engineer

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

  • Engineering Technical Assistant

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

more jobs »

Poll

"Is the Building Services industry lagging behind in the implementation of BIM?"