Manchester Civil Justice Centre enjoys the benefits of underfloor air conditioning

Published:  10 March, 2009

AET's Fexible Space System
AETís Flexible Space System provides adaptable and energy-efficient air conditioning for the new Manchester Civil Justice Centre.

AETís Flexible Space System has been installed in the £113 million Manchester Civil Justice Centre to provide efficient and highly adaptable air conditioning.

It is the largest court building to be built in the last 130 years, with a floor area of 34 000 m2 and 47 courtrooms. Few of the multi-purpose rooms in this 16-storey building are the same size and shape, so engineering designer Mott MacDonald selected the AET system as a versatile, low-energy mixed-mode ventilation system to ensure maximum utility value.

The system was installed by Axima Hills throughout office accommodation on four floors. Mixed-mode ventilation is achieved through a combination of underfloor air conditioning served by conditioned-air modules (CAMs) and free cooling via fan tiles, air-handling units for fresh air and windows.

Glan Blake Thomas, managing director of AET, explains, ĎFlexible Space was ideal for the installation at Manchester as it is easily incorporated into a complicated structural network and offers maximum flexibility for future changes through its moveable fan tiles.í

The underfloor system uses the plenum under raised access floors as a duct, with the building divided into zones depending on the potential use and occupancy density of the area. Each zone is supplied by chilled or warmed air by a CAM. The underfloor void is divided into supply- and return-air channels using relocatable, airtight baffles. Supply air is delivered into the occupied spaces by fan-assisted terminal units that are recessed into the floor and connected by data cabling for intelligent control. Air travels back to the CAM via return grills in the floor for mixing with fresh air.

The fan tile units do not have duct or pipe connections so they can easily be changed with other floor panels to respond to changes in office layouts.

For more information on this story, click here: Mar 09, 126

comments powered by Disqus

Search

Welcome

Welcome to Modern Building Services Online, the web edition of Modern Building Services (MBS) journal and the UK's most popular Building Services engineering site. Modern Building Services covers the entire Building Services Engineering industry. This site contains archived content from the journal, plus web-specific content.

When you go to our digital edition, you can also access the archive of digital editions.
August 2018: DIGITAL EDITION

ARCHIVE OF DIGITAL EDITIONS

Modern Building services has a group
on Linkedin - join us!

BESA conference 2018

Jobs

  • Building Energy Management Systems (BEMS) Engineer

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

  • Engineering Technical Assistant

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

  • Mechanical Engineer

      Coventry University is a dynamic, modern university with a proud tradition as a provider of high quality education and a focus on applied research. The University ranked 13th in the Guardian University Guide 2019 and was voted ‘Modern University of the......

more jobs »

Poll

"Is the Building Services industry lagging behind in the implementation of BIM?"



Calendar