Rhoss takes a more efficient approach to controlling chillers and heat pumps

Published:  12 January, 2010

Coolation, Rhoss, chillers, Heat pumps

Rhoss is now integrating as standard its Adaptive Function Plus predictive control system into its range of multi-scroll compressors and heat pumps. Using patented predictive control, the AFP system matches multi-scroll compressor operation to actual working conditions, reducing the energy consumption of chillers and heat pumps by up to 36% in winter mode and 18% in summer mode. Rhoss is represented in the UK by Coolmation Group.

Instead of using return-water temperature as the basis for control, AFP uses information from the load profile to control flow temperature according to load demands by managing the operation of each compressor. Maximising flow temperature in chiller mode can reduce energy consumption by 18%. Similarly, minimising flow temperature in heat-pump mode can reduce energy consumption by up to 36%.

AFP also has a ‘virtual tank’ function, so chiller and heat pump can operate with significantly less water — as little as 2 l/kW. In some cases, there will be no need for a buffer tank — or it can be made smaller.

For more information on this story, click here:  Jan10, 174

comments powered by Disqus

Search

Welcome

Welcome to Modern Building Services Online, the web edition of Modern Building Services (MBS) journal and the UK's most popular Building Services engineering site. Modern Building Services covers the entire Building Services Engineering industry. This site contains archived content from the journal, plus web-specific content.

When you go to our digital edition, you can also access the archive of digital editions.
August 2018: DIGITAL EDITION

ARCHIVE OF DIGITAL EDITIONS

Modern Building services has a group
on Linkedin - join us!

BESA conference 2018

Jobs

  • Building Energy Management Systems (BEMS) Engineer

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

  • Engineering Technical Assistant

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

  • Mechanical Engineer

      Coventry University is a dynamic, modern university with a proud tradition as a provider of high quality education and a focus on applied research. The University ranked 13th in the Guardian University Guide 2019 and was voted ‘Modern University of the......

more jobs »

Poll

"Is the Building Services industry lagging behind in the implementation of BIM?"



Calendar