R22 replacement air-conditioning can achieve 80% higher COP

Published:  07 April, 2010

Mitsubishi Electric, air conditioning, R22, R410A
Mitsubishi Electricís latest Replace systems for R22 system can increase COPs by up to 80%.

The second generation of Mitsubishi Electricís R410A City Multi Replace models offer an 80% increase in COP, a halving of installation time and a reduction in installation costs of up to 40% when replacing an R22 air-conditioning system that is 10 years old. The City Multi YJM Replace units join the existing splits Replace line up.

Mitsubishi Electric has over five yearsí experience in the Replace VRF market and even longer in the splits sector.

The City Multi YJM Replace model is a modular system that comes in both heat-pump and standard size small module with cooling capacities from 22 to 100 kW and heat recovery in the standard larger model (22 to 33 kW). All currently available City Multi indoor units can be used with the Replace model, and there is also the potential to upgrade the R22 systems of other manufacturers.

Many elements of an existing R22 system can be used ó including all piping, control wiring, power wiring and circuit breakers. Replacing a 10-year-old R22 system with a modern unit of the same capacity will reduce power consumption by up to 45% and increase COP by up to 80%.

A new system automatically charges itself with R410A and flushes mineral oil while operating in either heating or cooling mode.

For more information on this story, click here: April10, 83

comments powered by Disqus

Search

Welcome

Welcome to Modern Building Services Online, the web edition of Modern Building Services (MBS) journal and the UK's most popular Building Services engineering site. Modern Building Services covers the entire Building Services Engineering industry. This site contains archived content from the journal, plus web-specific content.

When you go to our digital edition, you can also access the archive of digital editions.
December 2018: DIGITAL EDITION

ARCHIVE OF DIGITAL EDITIONS

Modern Building services has a group
on Linkedin - join us!

Jobs

  • Senior Building Services Engineer

      Invitations are invited from experienced Building Services Engineers to assist in the development of a new division within an established professional practice. The projects will be predominantly with Defence-related and Government establishments but w......

  • Building Energy Management Systems (BEMS) Engineer

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

  • Engineering Technical Assistant

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

more jobs »

Poll

"Is the Building Services industry lagging behind in the implementation of BIM?"