Supermarket cooling provides heat source for domestic hot water
Published:  July 2010
PassivHaus, Dimplex, DHW

Heating from refrigeration and cooling circuits in this supermarket provides the energy for a Dimplex heat pump that generates domestic hot water.

The first supermarket to be built to PassivHaus standards in the British Isles includes a Dimplex ground-source heat pump that draws energy from refrigeration and cooling systems to supply domestic hot water. The Tesco sore in Tramore, County Waterford, is built to very high levels of air tightness and insulation, so water heating is an important consideration in the overall performance of the building. Such buildings typically have an annual energy consumption less than 15 kWh/m2.

The DHW system was designed by Dimplex and Dynamic Energy Solutions and installed by Geothermal Solar of County Kildare. It easily meets the total hot-water requirement for the store — including staff canteen and washrooms, and customer washrooms.

The Dimplex high-temperature ground-source heat pump can deliver flow temperatures up to 70°C. Typical source temperatures from the cooling system are 25 to 28°C, so the heat pump can easily deliver flow temperatures of 60 to 65°C with a COP of about 4.

The heat pump was part of a complete pre-assembled plant room that was delivered to site to be plumbed in.

Fergal McEntee of Dynamic says, ‘This application looks at the energy requirements for supermarkets and has opened the business community’s eyes to the possibilities for heat pumps, particularly with regard to using them to provide hot water. As a result of this installation, we are now talking to commercial clients in a wide variety of sectors.’

Other features of this project include PV panels, wind turbine, rainwater harvesting and permeable paving in the car park, natural refrigerants in cooling systems, triple glazing throughout and roof lights to exploit natural daylight.


For more information on this story, click here: July 10, 120



  • Show
E-mail Updates
Poll

We're hearing occasional reports that the Building Services industry is starting to pick up again. Does this match your experience?

  • Yes, we're seeing a noticable upturn.
  • Yes, we're seeing a slight upturn
  • I have not suffered any decline in business in the last 12 months
  • No, no change
  • No, things are getting worse
Calendar

Webmaster
Privacy Policy

© Modern Building Services - Portico Publishing Ltd - 2004 - 2012

Web Counter by TrafficFile.com