Efficiency and low emissions start with good housekeeping

Published:  02 September, 2010

Nu-Way, burner
Delivering lower costs and carbon reductions — Mike Baker.

Modern burners and the technology they employ can play a crucial part in reducing emissions and energy consumption. Mike Baker looks at the latest techniques and products that can make such a big difference in keeping costs and emissions down.

With most heating equipment, the key to improving efficiency and reducing carbon emissions should always start with good housekeeping — and burners are no exception. Regular appliance servicing and maintenance will ensure maximum operating efficiency and reliability. Most of the leading burner manufacturers offer a range of spares and service contracts to suit all types of burner/boiler applications.

As with any heating and combustion equipment, it is critically important that all service or maintenance work is carried out by engineers who have been properly trained and are qualified. It can be tempting for the unqualified or inexperienced to try to undertake this themselves, but this is a recipe for potential disaster. Care must always be taken and, if in doubt, the equipment manufacturer can advise accordingly and provide a service engineer to call or arrange for the required training where appropriate.

When it comes to maintenance and identifying faults, electronic burner programmers offer an additional benefit, as many provide a fault history and improved diagnostics to aid the service engineer. This will ensure repair work can be carried out more easily and more quickly, so down-time will be reduced.

When looking to reduce costs and use less fuel, it is quite surprising how a small increase in efficiency can make a big difference. For example, an increase of just 1% in energy efficiency can reduce the fuel costs for a 500 kW natural-gas burner by up to £400 a year — corresponding to a CO2 reduction of about 1850 kg a year.

An important consideration is the burner control, either when the burner is first selected or when it is replaced. For example, a basic on/off (one stage) control may be acceptable for smaller burners up to 100 kW. However the additional cost of using improved control with high/low (2-stage) and modulation will easily be justified for larger burners.

Using high/low control instead of on/off can improve efficiency by up to 2%, with energy savings of about £800 a year and CO2 reduction of 3700 kg a year for natural gas or offering £1000 and 5300 kg a year for gas/oil.

Modulating controls can also improve efficiencies by a further 3 per cent compared to high / low, with savings of £1200 a year and CO2 reduction of 5500 kg a year with natural gas or £1600 and 7900 kg a year for gas oil.

Such controls regulate the number of times the burner has to start up and will also improve demand matching. Electronic burner programmers provide more precise modulating control of the air and fuel, increasing the repeatability of the air-fuel ratio and reducing air levels and flue losses.

Nu-Way, burner
Even small improvements in the efficiency of burners will yield substantial energy savings and reductions in CO2 emissions. Higher levels of control will achieve far more.

There are also control techniques used on very large burners offering outputs of 5 MW and more, such as electronic valve positioning. In addition, using a variable-speed drive with the fan motor to supply air for combus­tion air and oxygen trim with smaller burners, can further increase efficiency by 3 to 7%.

At the highest level, a 5 MW natural gas burner with an efficiency improvement of 8% would provide energy and cost savings per annum of about £33 000 and 148 000 kg in reduced CO2 emissions. For gas oil burners this would translate to £43 000 and 212 000 kg.

The Government has been highlighting the benefits of utilising energy-efficient solutions wherever possible. Most specifiers, contractors and end-users will be aware that investing in technology to increase operating efficiency will reduce emissions and save money in the long term. That is why manufacturers have invested in research and development to ensure energy efficiency is taken into account when bringing new products to market.

Utilising a low NOx burner is another way of reducing emissions, and it has become easier to source equipment offering this benefit. In addition to lower nitrogen-oxide emissions, these technologies offer improve burner turndown and minimisation of fuel and air imbalances within the burner.

 

Taking all this into account, the importance of selecting equipment and controls with a higher efficiency is clearly something that should not be overlooked, and burners have a key role to play in reducing emissions and energy consumption.

Mark Baker is director of Nu-Way’s burner division.

 



comments powered by Disqus

Search

Welcome

Welcome to Modern Building Services Online, the web edition of Modern Building Services (MBS) journal and the UK's most popular Building Services engineering site. Modern Building Services covers the entire Building Services Engineering industry. This site contains archived content from the journal, plus web-specific content.

When you go to our digital edition, you can also access the archive of digital editions.
December 2018: DIGITAL EDITION

ARCHIVE OF DIGITAL EDITIONS

Modern Building services has a group
on Linkedin - join us!

Jobs

  • Senior Building Services Engineer

      Invitations are invited from experienced Building Services Engineers to assist in the development of a new division within an established professional practice. The projects will be predominantly with Defence-related and Government establishments but w......

  • Building Energy Management Systems (BEMS) Engineer

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

  • Engineering Technical Assistant

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

more jobs »

Poll

"Is the Building Services industry lagging behind in the implementation of BIM?"