Airedale introduces low-energy approaches to data-centre cooling

Published:  11 October, 2010

Among a range of new cooling solutions from Airedale is an R410A chiller with a cooling capacity from 150 to 450 kW and which can achieve up to 98% free cooling, based on London conditions. The DeltaChill Freecool (left) combines the latest fan technology with micro-channel coils to achieve an ESEER (European seasonal EER) above 4.5.

The other cooling solutions are for data centres.

The 60 kW InRak cooling system is designed to fit in between server racks and includes a direct-expansion/chilled-water dual-cooling option. When integrated with the DeltaChill FreeCool chiller or the BluCube condensing unit (see below), very high efficiencies can be obtained.

The OnRak rear-door heat exchanger adds only 200 mm to the depth of the rack and can provide 3 to 33 kW of cooling. This system has an EER of up to 166. Over a year, it can achieve energy savings of up to 88% compared with a traditional airside unit of the same capacity.

Airedale, data centre, CRAC, air conditioning, free cooling

The ACE (Active Cabinet Exhaust) unit is installed on top of the server cabinet with no loss of floor space (top of story). Its twin EC fans (N+1) provide up to 18 kW of cooling by removing hot air and ducting it directly to an Airedale CRAC unit linked to free-cooling chillers.

The BluCube is a cost-effective R410A condensing unit with heat-pump variant and variable capacity control. It can be matched to a variety of industry-standard air-handling units and also be integrated with InRack or SmartCool.

For more information on this story, click here:  Oct 2010, 172

comments powered by Disqus

Search

Welcome

Welcome to Modern Building Services Online, the web edition of Modern Building Services (MBS) journal and the UK's most popular Building Services engineering site. Modern Building Services covers the entire Building Services Engineering industry. This site contains archived content from the journal, plus web-specific content.

When you go to our digital edition, you can also access the archive of digital editions.
February 2018: DIGITAL EDITION

ARCHIVE OF DIGITAL EDITIONS

Modern Building services has a group
on Linkedin - join us!

Jobs

  • Intermediate / Senior Mechanical Engineer

    The Mechanical team undertake the design and specification of a range of Mechanical building services in a lead or supporting role, depending on project complexity and scale. You should demonstrate a flexible approach to design and team working and wil......

  • Senior Urban Designer

     Applicants will be Master’s Degree qualified Architects / Urban Designers, with a strong portfolio of work highlighting a variety of projects at a range of scales and types, with strong focus on regeneration, infrastructure-led projects and major develo......

  • Principal Structural Engineer

    We are currently recruiting on behalf of a global client, with a diverse range of award winning projects to their name. Their experience spans a host of market sectors, including transport, infrastructure, defence, scientific, education, high-tech and ......

more jobs »

Poll

"Is the Building Services industry lagging behind in the implementation of BIM?"