Turbomiser chillers slash cooling energy use at a data centre

Published:  01 September, 2011

Cool-Therm, Turbomiser chiller
Huge reductions in the energy used for cooling a data centre are being achieved following the installation of Turbomiser chillers to replace existing equipment.

Energy savings of 55% have been achieved following the replacement of existing cooling plant with new Turbomiser chillers at the west London data centre of Colt Technology. The new chillers have also improved reliability and reduced maintenance costs.

Colt Data Centre Services asked Cool-Therm to provide a turnkey package, matching the existing cooling load of the data centre and maintaining cooling at all times during the changeover.

Six chillers were installed, and Cool-Therm advised that the most efficient method of operation would be to run them all together under inverter control, at the same time maximising condenser efficiency by using all the heat-exchanger surfaces to reject heat.

Operating efficiency was also improved by increasing the flow/return chilled-water temperatures from 6/12°C to 8/14°C.

A monitoring system was installed to compare energy consumption against the previous system.

Guy Ruddock, VP operations for Colt Data Centre Services, comments, ‘The energy-efficiency expertise and experience gained is now being applied across the Colt estate by local teams.’

For more information on this story, click here: September 2011, 125

comments powered by Disqus

Search

Welcome

Welcome to Modern Building Services Online, the web edition of Modern Building Services (MBS) journal and the UK's most popular Building Services engineering site. Modern Building Services covers the entire Building Services Engineering industry. This site contains archived content from the journal, plus web-specific content.

When you go to our digital edition, you can also access the archive of digital editions.
December 2018: DIGITAL EDITION

ARCHIVE OF DIGITAL EDITIONS

Modern Building services has a group
on Linkedin - join us!

Jobs

  • Senior Building Services Engineer

      Invitations are invited from experienced Building Services Engineers to assist in the development of a new division within an established professional practice. The projects will be predominantly with Defence-related and Government establishments but w......

  • Building Energy Management Systems (BEMS) Engineer

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

  • Engineering Technical Assistant

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

more jobs »

Poll

"Is the Building Services industry lagging behind in the implementation of BIM?"