University of Greenwich cuts AHU bill by £10 000

Published:  03 December, 2012

ABB, variable speed drive, AHU
ABB drives are substantially reducing the energy consumption of air-handling units at Greenwich University.

The University of Greenwich is set to save £10 000 a year on its air-handling costs across its three campuses following the installation of ABB variable-speed drives for a number of buildings. Additional savings from future projects could cut running costs by another £4000 a year. David Blackburn, building-services engineers in the university’s building-services department, said. ‘We were looking for payback times on the projects of about five years, yet most were much quicker than that.’

The university has a 5-year target to reduce its carbon emissions. David Blackman explains, ‘We worked on the premise that most of the air-conditioning plant is over-rated and that were could reduce the speed of the fans without affecting the airflow adversely.

ABB drives-alliance member Mid Kent Electrical (MKE) was called in to investigate the potential for using variable-speed drives on AHUs in buildings on the Medway, Greenwich and Avery Hill campuses.

A survey on the Medway site found that many fans had rated speeds and powers less than that of the motors. Fans were either being run too fast or their speed reduced using pulleys. When the original system was set up, airflow was adjusted by setting dampers on vents at room level.

Monitoring of one fan motor on the Medway campus on direct-online operation for two days showed the 4 kW motor consuming 3.353 kW for an annual running cost of £871. Running the motor for two days with an ABB drive consumed an average of 2.087 kW for an annual cost of £542.

Based on these results, it was estimated that installing variable-speed drives on motors with a total installed power of 127 kW would save £10 472 a year in running costs and reduce CO2 emissions by over 57 t a year.

Further investigation on the Greenwich campus revealed the potential for saving £2040 a year and reducing CO2 emissions by 5 t.

Avery Hill campus could save £2157 a year, with a cut in CO2 emissions of 19 t a year.

For more information on this story, click here: December 2012, 120

comments powered by Disqus

Search

Welcome

Welcome to Modern Building Services Online, the web edition of Modern Building Services (MBS) journal and the UK's most popular Building Services engineering site. Modern Building Services covers the entire Building Services Engineering industry. This site contains archived content from the journal, plus web-specific content.

When you go to our digital edition, you can also access the archive of digital editions.
August 2018: DIGITAL EDITION

ARCHIVE OF DIGITAL EDITIONS

Modern Building services has a group
on Linkedin - join us!

BESA conference 2018

Jobs

  • Building Energy Management Systems (BEMS) Engineer

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

  • Engineering Technical Assistant

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

  • Mechanical Engineer

      Coventry University is a dynamic, modern university with a proud tradition as a provider of high quality education and a focus on applied research. The University ranked 13th in the Guardian University Guide 2019 and was voted ‘Modern University of the......

more jobs »

Poll

"Is the Building Services industry lagging behind in the implementation of BIM?"



Calendar