Data-centre cooling saves energy and creates revenue

Published:  06 January, 2014

SemperTec, data centre cooling

SemperTec’s Delta-T cooling solution for data centres is based on installing cooling units in the rows of racks, rather than CRAC (computer-room air-conditioning) units around the perimeter. By localising cooling in this way, the number of IT racks in a room can be increased by 16%. An example put forward by SemperTec is 352 racks being increased to 408, with the potential revenue from those 56 extra racks being over £1 million a year. And there’s an electricity cost saving of over £77 000 a year compared with CRAC units.

Delta-T units protrude slightly forward from the server racks (see photo). Centrifugal fans deliver cool air sideways along the front of the server racks. This cooled air is drawn through the server racks and discharged at the rear.

A significant improvement to overall operating efficiency can be achieved by letting the hot air return to the cooling unit through the server racks themselves via interconnecting grilles to create a 300 mm-deep air plenum.

Discharging cooled air direct into the space obviates the need for a large floor void and grilles to let air up into the cold aisles. Fan energy is significantly reduced, by around 15%.

The cooling energy can be from chilled water or DX using R407C. To avoid condensation, the evaporating temperature is 13°C.

Delta-T units can be installed as a data centre is populated.

For more information on this story, click here: Jan 2014, 170

comments powered by Disqus

Search

Welcome

Welcome to Modern Building Services Online, the web edition of Modern Building Services (MBS) journal and the UK's most popular Building Services engineering site. Modern Building Services covers the entire Building Services Engineering industry. This site contains archived content from the journal, plus web-specific content.

When you go to our digital edition, you can also access the archive of digital editions.
December 2018: DIGITAL EDITION

ARCHIVE OF DIGITAL EDITIONS

Modern Building services has a group
on Linkedin - join us!

Jobs

  • Senior Building Services Engineer

      Invitations are invited from experienced Building Services Engineers to assist in the development of a new division within an established professional practice. The projects will be predominantly with Defence-related and Government establishments but w......

  • Building Energy Management Systems (BEMS) Engineer

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

  • Engineering Technical Assistant

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

more jobs »

Poll

"Is the Building Services industry lagging behind in the implementation of BIM?"