Samsung launches R410A VRF air-conditioning system

Samsung has launched an R410A version of its Digital Variable Multi VRF air-conditioning system. The launch of DVM2 is the first stage of introducing over a hundred new products during 2006. The system uses Copeland digital scroll technology, which is based on a compressor running at constant speed and matching its capacity to system demand by continuously loading and unloading to provide time-averaged capacity control. It provides capacity control down to 10%. The power consumption of an unloaded compressor is reduced to only 10% that of full-load power. This approach to capacity control is said to avoid the need for the oil-collection cycle that is needed with compressors running at variable speed, because of the excellent oil-return characteristics arising from the compressor always discharging at 100%. The new range comprises four outdoor modules which combine to provide systems from 8 to 48 hp in 2 hp increments. Index pipe runs can be up to 170m (195 m equivalent), with total pipe lengths running to 300 m. The range of indoor units includes one-way, 2-way and 4-way cassettes. There are also built-in duct, silhouette duct and a new slim duct. There are two types of wall unit — premium and classic — and a ceiling unit. Indoor units have cooling capacities from 2.2 to 14 kW. The DVM2 range is initially available for cooling only and qualifies for Enhanced Capital Allowances. Further launches this year will include a 3-pipe heat-recovery version and a Mini DVM system. A comprehensive range of controllers combines simplicity with sophistication. They include a Data Management Server with an embedded web server that provides control via a web browser of up to 256 indoor units. Multiple users are supported, with a password system for different levels of control.
Related links:



modbs tv logo

‘Red tape scrapping is welcome – but more policy changes are needed’

The CEO of heat pump manufacturer Aira UK has said the government’s new proposals to scrap planning red tape for the installation of heat pumps in the UK will be a big breakthrough for the industry and consumers – but more policy changes are needed.

New procurement rules for NHS suppliers

New procurement rules mean NHS suppliers will need to demonstrate their green credentials so the NHS can achieve its target of becoming net zero for directly-controlled emissions by 2040, with an ambition to reach an 80% reduction in its carbon emissions between 2028 to 2032.