British Library boosts the efficiency of its heating system at St Pancras

Published:  01 December, 2010

G&D Higgins, space heating
More efficient space heating for the British Library at St Pancras has been achieve by the installation of condensing boilers by G&D Higgins.

A major boiler replacement and heating-system upgrade at The British Library, St Pancras, has been carried out in ‘textbook’ style by contractor G&D Higgins. The building has the Magna Carta, Leonardo da Vinci’s original notebook, the first edition of The Times (18 March 1788) and Beatles’ manuscripts in its care.

To reduce the building’s carbon footprint, the project included replacing two non-condensing 1.75 MW steel boilers used for space heating in Winter and dehumidification reheat in the Summer. These boilers served the very-low-temperature hot-water circuit via plate heat exchangers.

They were replaced with three 600 kW Ygnis boilers with Dunphy fully modulating natural-gas burners. They had to make judicious use of branch connections to maintain existing plant load throughout the 112 000 m2 building during what turned out to be a continuously cold Winter.

Further energy savings were achieved using an Ygnis Totelco extractive economiser in the flue. With the system on full fire, a further 50 kW of heat recovery is expected.

Optimising the heating system to match today’s use of the 1980s building involved considerable resizing and replacement of complex pipework to reduce pumping losses.

For more information on this story, click here: December 10, 136

comments powered by Disqus

Search

Welcome

Welcome to Modern Building Services Online, the web edition of Modern Building Services (MBS) journal and the UK's most popular Building Services engineering site. Modern Building Services covers the entire Building Services Engineering industry. This site contains archived content from the journal, plus web-specific content.

When you go to our digital edition, you can also access the archive of digital editions.
December 2018: DIGITAL EDITION

ARCHIVE OF DIGITAL EDITIONS

Modern Building services has a group
on Linkedin - join us!

Jobs

  • Senior Building Services Engineer

      Invitations are invited from experienced Building Services Engineers to assist in the development of a new division within an established professional practice. The projects will be predominantly with Defence-related and Government establishments but w......

  • Building Energy Management Systems (BEMS) Engineer

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

  • Engineering Technical Assistant

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

more jobs »

Poll

"Is the Building Services industry lagging behind in the implementation of BIM?"