The long game

AroTHERM

With the upcoming changes to building regulations as part of the Future Homes Standard, there is no doubt that heat pumps are set to play a significant role in the journey towards decarbonising heat in our homes.

Homes – both new and existing – account for 20% of greenhouse gas emissions in the UK1. To reduce the carbon footprint of our homes, the UK Government has committed to introducing a Future Homes Standard by 2025, which includes plans to phase out fossil-fuel heating from all new homes in favour of heat pumps and other low carbon technologies2. By then, we will reach the next milestone in the phase-down of F-gases as dictated in the F-gas regulations. Although the two pieces of legislations are separate, their combination has opened up a unique opportunity for Vaillant – which is more well-known as a boiler manufacturer – to introduce a different refrigerant to the heat pump market to deliver comfort in people’s homes whilst minimising their carbon footprint.

Phase-down of refrigerants

While it is commonly understood that heat pumps are a green solution, there are differing environmental impacts and operating efficiencies of the various refrigerants in use within heat pumps on the market today. Historically, the most commonly used heat pump refrigerant was R410A, but with a GWP (Global Warming Potential) of 2088, it is currently being phased out of the market under the F-gas regulation. As a result, some manufacturers are now turning to R32 for their heat pumps.

However, this substance has a GWP of 675. So, every tonne of R32 released into the atmosphere has the same greenhouse gas effect as the equivalent of 675 tonnes of CO2. As a manufacturer of heating rather than cooling appliances, we are able to go down a different route - using R290.  

A better alternative

R290 is the technical name for the natural refrigerant also known as propane. It is already commonly used in many parts of our daily life, such as in refrigerators, air conditioning or even hairspray. It has a GWP of 3 – 225 times lower than R32, and 696 times less than R410a. Every tonne of R290 used is equivalent to only 3 tonnes of carbon emissions from CO2, resulting in a much lower carbon footprint.

By the time the Future Home Standard comes into effect, the total amount of emissions equivalent to CO2 allowed will only be 31% compared to the baseline, with a further reduction to 21% in 2030. So, whilst R32 is undoubtedly a greener solution than R410A, the likely level of growth for the heat pump market means that it will be unacceptable under F-gas standards with some predictions stating as early as 2024-26. By using R290 instead of R32 in one of our heat pumps, not only is the it protected from the reduced availability of HFC refrigerants in the years to come, but it will also make a bigger contribution towards the country’s target to reach net-zero by 2050. What’s more, heat pumps which utilise natural refrigerants such as R290 are able to use less volume per kW, allowing them to achieve the same, or greater results than counterparts, more efficiently.

More hot water

The other key reason why R290 is a better choice is its ability to deliver more hot water to the hot water cylinder and at point of use.

Most heat pumps with R32 as the refrigerant, can only handle flow temperatures of up to 65oC in a hot water system. This means that a back-up heater (direct electric immersion heater) is required in the hot water cylinder to store the hot water above 60oC – the point at which legionella bacteria is killed off. The lower flow temperature also results in less useable hot water in the tank.

As an example; the performance envelope of R290 allows the Vaillant aroTHERM plus to get hot water at 75oC straight from the heat pump’s refrigerant circuit, so that the water in the hot water cylinder will be 70oC without the use of a direct electric immersion heater to protect residents from legionella. This results in a more effective system which can deliver 376 litres of useable hot water - equivalent to about six standard showers*.

Closing the skills gap

With heating trends changing all the time and new regulations being introduced, it’s essential for installers to keep up to date. But currently, there are not enough qualified engineers to design and install the amount of low-carbon, or low temperature heating systems needed to implement the expected increase in these technologies in forthcoming years. The HPA has estimated that a total of 69,500 installers would be needed by 2035 to deploy the number of installations necessary in order for the UK to stay on track and achieve net-zero by 20501

We, along with other manufacturers, offer a range of informative online courses to upskill installers and engineers about heat pumps and ‘green’ solutions. But these alone, are not enough. Engineers need a wide range of up-to-date skills, knowledge and competencies that reflect the latest technologies and standards to help them to design and install quality low-carbon heating systems, such as heat pumps, for their customers. That’s why government needs to encourage more investment in training, and all parties in both the refrigerant and heating industries need to work together to successfully roll out relevant courses that have been built on a robust qualification criteria and teaching framework.

Trusted technology

Due to the technology involved, many manufacturers of heat pumps started out as makers of air conditioning units. Vaillant on the other hand, evolved from being a gas boiler manufacturer. This means that we have spent 140 years working with combustible gases and are in a strong position to deliver comfort in homes in an energy efficient, quiet, and safe way.

Heat pumps are enabling consumers to heat their homes and generate hot water with zero carbon emissions at point of use. As a company which has been synonymous with heating solutions for 140 years, we are well-placed to use a different refrigerant with a much lower GWP to truly deliver comfort without the carbon footprint. By also providing the right training to increase and develop skills across the refrigerant and heating industry, engineers, installers and manufacturers can all work together to implement heat pump technologies to meet the climate challenge.

*Based a standard 12 litres a minute shower for five minutes.

Steve Keeton is Director of External Affairs and Future Portfolio at Vaillant

Related links:
Related articles:



modbs tv logo

‘Red tape scrapping is welcome – but more policy changes are needed’

The CEO of heat pump manufacturer Aira UK has said the government’s new proposals to scrap planning red tape for the installation of heat pumps in the UK will be a big breakthrough for the industry and consumers – but more policy changes are needed.

New procurement rules for NHS suppliers

New procurement rules mean NHS suppliers will need to demonstrate their green credentials so the NHS can achieve its target of becoming net zero for directly-controlled emissions by 2040, with an ambition to reach an 80% reduction in its carbon emissions between 2028 to 2032.